The Ermenrich Zing TC27 digital multimeter is used for testing electrical equipment and electrical circuits. Its broad functionality allows you to use it not only at home but also for professional work. The multimeter is an excellent choice for engineers, electricians, repairmen, and other technicians. The Ermenrich Zing TC27 multimeter is a True RMS device that guarantees highly accurate measurements of non-sinusoidal signals.

The multimeter has 7 basic functions: It measures DC and AC voltage, DC and AC current, resistance, frequency, capacitance, duty cycle, and temperature. A thermocouple-based sensor is used for temperature measurement. The Smart function allows you to measure some basic quantities without having to manually adjust the multimeter: This function will automatically recognize the signal.

The multimeter can locate open and short circuits, test diodes, and determine the phase. All of the readouts are displayed on the large backlit color screen - as digits and a graphic scale. There is a hold function available. The device is powered by standard batteries.

Key features:

  • True RMS calculations
  • The functions of a voltmeter, ammeter, ohmmeter, capacitance meter, frequency meter, duty cycle meter, and a thermocouple sensor are combined in just one tool
  • Smart function – automatic signal recognition (resistance, voltage, and continuity test)
  • Non-contact NCV high voltage detector, phase detection (Live), diode test, continuity test, hold function
  • Powered by standard batteries

The kit includes:

  • Digital multimeter
  • Probes
  • Pouch
  • User manual and warranty card
BrandErmenrich
Warranty5 лет
EAN5905555017679
Package size (LxWxH)17x9x6 cm
Shipping Weight0.4 kg
Selection of the measuring limitautomatic
Basic functions voltmeter, ammeter, ohmmeter, capacitance meter, frequency meter, duty cycle meter, thermocouple
DC voltage measuring limit60mV/600mV/6V/60V/600V: error ±(0.5%+3)
AC voltage measuring limit6/60/600V: error ±(0.8%+3)
DC current measuring limit600mA/10A: error ±(1.2%+3)
AC current measuring limit600mA/10A: error ±(1.5%+3)
Resistance measuring limit600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ: error ±(1.0%+3)
Capacity measuring limit6nF/60nF/600nF/6µF/60µF/600µF/6mF: error ±(3.0%+5)
Frequency measurement limits60Hz/600Hz/6kHz/60kHz/600kHz/6MHz/10MHz: error ±(1.0%+3)
Duty cycle measurement range1–99%: error ±(3.0%+3)
Diode test+ (0–3V)
Non-contact voltage detection (NCV)yes
True RMS yes
Hold functionyes
Automatic recognition function (Smart)+ (only for DC and AC voltage, resistance and continuity)
Phase detector (Live)yes
Overvoltage categoryCAT III 600V
DisplayVA
Display counts6000
Display backlightyes
Graphic scaleyes
Flash lightyes
Safety standardsEN61010-1,-2-030; EN61010-2-033; EN61326-1
Operating temperature range,°C−40... +1000 (−40... +1832): error ±(1.0%+3)
Continuity test+, combined with resistance measurement mode (<50Ω)
Power supply4 AAA batteries (not included)
Low battery status indicatoryes
Auto power offyes