Ermenrich Ping ET60 Earth Resistance Tester is a device that is designed to measure earth resistance in a range from 0 to 4kΩ. It is equipped with a built-in LCD screen, three test cables of varying lengths, and two earthing rods. The device runs on batteries, has an auto power off function, and notifies you of the need to replace batteries if their charge is insufficient. It is recommended to carry out measurements and diagnostics of equipment at a high battery charge level; otherwise, the results may be unreliable.
The device stores measurements in memory, records maximums, minimums and average values, and per-forms relative measurements using a reference value. The Data Hold function is designed to “freeze” the measurement results on the device screen in situations where you need to work with them later.
Ermenrich Ping ET60 is a measuring device used for testing power distribution lines, planning lightning protec-tion systems, diagnosing high-voltage poles, buildings, communication stations, internal wiring, electrical equipment, etc. It has high measurement accuracy and is suitable for use in professional work.
Key Features:
- Measuring earth resistance using the DC conversion method
- Earth voltage measurement using the numerical average rectification method
- Memory for 100 measurement groups as well as storing the minimum, maximum, and average values
- On-screen reading hold function, calculation based on reference values
- Powered by standard batteries, auto power off function, and a low battery alert
The kit includes:
- Earth resistance tester
- Test cables – 3 pcs.
- Auxiliary earthing rods – 2 pcs.
- Case bag
- User manual and warranty card
Brand | Ermenrich | Warranty | 5 лет | EAN | 5905555017402 | Package size (LxWxH) | 33x26x9 cm | Shipping Weight | 2.36 kg | Data save/read function | yes | Data hold function | yes | Limit value memory (Min/Max) | yes | Average value memory (AVG) | yes | Relative value measurement (REL) | yes | Display backlight | yes | Graphic scale | yes | Low battery status indicator | yes | Auto power off | yes | Earth resistance measurement range | 0–29.99Ω: error (±2%+6), resolution 0.01Ω; 30–99.9Ω: error (±3%+3), resolution 0.1Ω; 100–999Ω: error (±3%+3), resolution 1Ω; 1.00–4.00kΩ: error (±3%+3), resolution 10Ω | Earth voltage | 0–200V (50–60Hz): precision (±1%+5), resolution 0.1V | Measuring method | two-lead, three-lead | Earth resistance measurement parameters | test current 3mA, 800Hz | Memory | 100 groups | Overvoltage category | CAT III 1000V, CAT IV 600V | Display | yes | Safety standards | EN61010-1, EN61557-3, EN61326-1 | Power supply | 8 AA batteries (not included) |
|